1. Technical parameter
Specification |
3 phase 3 wires, 3 phase 4 wires |
|
Voltage |
Reference voltage |
3×100V、 3×380V、3×57.7/100V、 3×220/380V |
Consumption |
<10VA(Single phase) |
|
Impedance |
>2MΩ |
|
Accuracy class |
Error±0.2% |
|
Current |
Input current |
3×1(6)A,3×1(6)A(Outlay transformer),3×10(80)A,3×10(100)A(Outlay transformer) |
Consumption |
<1VA(Single phase rated current) |
|
Accuracy class |
Error±0.2% |
|
Power |
Active, reactive, apparent power, error±0.5℅ |
|
Frequency |
45~65Hz, Error±0.2% |
|
Temperature |
-40℃~99℃ |
|
Energy |
Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2) |
|
Clock |
≤0.5s/d |
|
Energy pulse output |
1 active optocoupler output, 1 reactive optocoupler output |
|
Switching output |
1 Switching output, Maximum allowed voltage: DC/AC 220V |
|
Switching input |
1 optocoupler input,Maximum allowed voltage: DC/AC 220V |
|
Width of pulse |
80±20ms |
|
Pulse constant |
6400imp/kWh,400imp/kWh(Correspond with the basic current) |
|
Interface and communication |
RS485:Modbus RTU |
|
Range of communication address |
Modbus RTU:1~ 247; |
|
Baud rate |
1200bps~19200bps |
|
Relative temperature |
-25℃~+55℃ |
|
Relative humidity |
≤95℅(No condensation) |
2. Basic & Optional Function
Function |
Function description |
Function provide |
Measurement of kWh |
Active kWh (positive and negative) |
■ |
Reactive kWh (positive and negative) |
■ |
|
A, B, C phase positive active kWh |
■ |
|
Measurement of electrical parameters |
U、IP、Q、S、PF、F |
■ |
■ |
||
Measurement of |
2~31ST Voltage and current harmonic |
■ |
LCD Display |
8 bits section LCD display, background light |
■ |
Key programming |
4 keys to communication and set parameters |
■ |
Pulse output |
Active pulse output |
■ |
Reactive pulse output |
□Note 1 |
|
Clock pulse output |
□Note 1 |
|
Multi-tariff and functions |
Active switch input |
□Note2 |
Switch output |
□Note 2 |
|
Adapt 4 time zones, 4 time interval lists, 14 time interval by day and 4 tariff rates |
□ |
|
Max demanded kWh and time happened |
□ |
|
Frozen data on last 48 months, last 90days |
□ |
|
Date, time |
□ |
|
Communication |
Infrared communication |
■ |
The first communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU |
□ |
|
The second communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU |
□Note 2 |
|
Temperature measurement |
Support 3 outlay NTC temperature |
□Note 3 |
“■” means standard, “□” means optional.
Note:
1. Reactive pulse output, clock pulse output and switching output: Choose one of these three.
2. Active switching, the second communication path: Choose one of these two.
3. Both 1 and 2 cannot be chosen while choosing temperature measurement.